Hantek HAP11L3000 AC Power Supply - 3KVA by Hantek (SKU: PRD-1768587232274-hantek-hap11l3000-ac) — Verified genuine industrial tool available on IndustryGuru with fast dispatch across India.



| Parameter | HAP11L3000 |
| Detail | Output function Analog voltage per country |
| Detail | Isolation function Built-in isolation transformer |
| Wiring method Input | single-phase two-wire Output: single-phase two-wire |
| Output | single-phase two-wire |
| Detail | Number of output phases Single-phase two-wire + PE |
| Detail | Output mode Single-phase standard sine wave output |
| Output voltage 0-300.0V Rated voltage | 220.0V |
| Voltage setting accuracy Accuracy | ≤0.1% Resolution: 0.1V |
| Rated current | 14A |
| Output power | 3KVA |
| Output frequency | 45-65Hz, |
| Frequency setting accuracy Accuracy | ≤0.05% Resolution: 0.1Hz |
| Frequency stability | ≤0.05% |
| Voltage distortion | <2% (linear load) |
| Response time (technology) | ≤2ms |
| Voltage sudden change response time | ≤20ms |
| Crest factor | 1.41±0.1 |
| Source voltage effect | ≤1% |
| Load effect | ≤1% |
| Efficiency | >90% |
| Display mode | 7-inch LCD display |
| Voltage measurement accuracy Accuracy | 0.2% FS + 0.3% display value Resolution: 0.1V |
| Frequency measurement accuracy Accuracy | 0.05% Resolution: 0.1Hz |
| Current measurement accuracy Accuracy | 0.3% FS + 0.5% display value Resolution: 0.1A/1A |
| Detail | Automatic memory function Setting parameters are automatically memorized and automatically recalled on power-up |
| Shortcut group recall | 10 sets of quick-operation parameter groups for fast switching |
| Detail | Real-time adjustment function Real-time adjustment of the output voltage setting in the start-up state |
| Overload capacity | 105% < overload≤ 110% cuts off output after 60 seconds |
| Detail | 110% < overload≤ 120% cuts off output after 5 seconds |
| Detail | Protection device Output overcurrent, overload protection, output short circuit protection, overheating protection |
| Communication interface Standard | USB, RS232, CAN/RS485, Optional: LAN |
| Detail | Input phases Single-phase two-wire + PE |
| Input voltage range | 220V±10% |
| Input frequency range | 50/60Hz |
| Operating temperature | 0~40℃ |
| Operating humidity | 20~90%RH (non-condensing) |
| Size L×W×H (mm) | 500×430×132 |
| Weight (Kg) | 19.6Kg |
| Detail | As per Brand policy |
Parameter HAP11L3000 Output function Analog voltage per country Isolation function Built-in isolation transformer Wiring method Input: single-phase two-wire Output: single-phase two-wire Output: single-phase two-wire Number of output phases Single-phase t...